Skip to main content

Table 4 Range of variables in Figures 25 as indicated by gray scales. The highest value (indicated by black shading) and the lowest value (indicated by white) are given for each variable for which kriged maps were produced.

From: Modeling spatial patterns of fuels and fire behavior in a longleaf pine forest in the Southeastern USA

  

Range

  
  

lowest

highest

 

Unit

Variable

(white)

(black)

units

Burn-only

   

Plot 6

    
 

mean fire temperature

88

278

C

 

pre-burn standing biomass

37

179

g m−2

 

pre-burn 1–1000 hour fuel mass

315

1838

g m−2

 

post-burn standing biomass

59

124

g m−2

 

post-burn 1–1000 hour fuel mass

255

890

g m−2

 

post-burn litter mass

400

1606

g m−2

Herbicide-and-burn

   

Plot 4

   
 

mean fire temperature

104

254

C

 

pre-burn litter mass

713

3642

g m−2

 

pre-burn 1–1000 hour fuel mass

48

455

g m−2

Plot 7

   
 

mean fire temperature

85

232

C

 

pre-burn standing biomass

62

147

g m−2

 

pre-burn litter mass

502

1775

g m−2

Plot 12

   
 

mean fire temperature

185

801

C

 

pre-burn standing biomass

61

323

g m−2

 

pre-burn litter mass

423

1324

g m−2